ADC12 Registers

20-23

ADC12

ADC12CTL1, ADC12 Control Register 1

15

14

13

12

11

10

9

8

CSTARTADDx

SHSx

SHP

ISSH

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

7

6

5

4

3

2

1

0

ADC12DIVx

ADC12SSELx

CONSEQx

ADC12

BUSY

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

r−(0)

Modifiable only when ENC = 0

CSTART
ADDx

Bits
15-12

Conversion start address. These bits select which ADC12
conversion-memory register is used for a single conversion or for the first
conversion in a sequence. The value of CSTARTADDx is 0 to 0Fh,
corresponding to ADC12MEM0 to ADC12MEM15.

SHSx

Bits
11-10

Sample-and-hold source select
00

ADC12SC bit

01

Timer_A.OUT1

10

Timer_B.OUT0

11

Timer_B.OUT1

SHP

Bit 9

Sample-and-hold pulse-mode select. This bit selects the source of the
sampling signal (SAMPCON) to be either the output of the sampling timer or
the sample-input signal directly.
0

SAMPCON signal is sourced from the sample-input signal.

1

SAMPCON signal is sourced from the sampling timer.

ISSH

Bit 8

Invert signal sample-and-hold
0

The sample-input signal is not inverted.

1

The sample-input signal is inverted.

ADC12DIVx

Bits
7-5

ADC12 clock divider
000 /1
001 /2
010 /3
011 /4
100 /5
101 /6
110 /7
111