LCD Controller Operation

18-6

LCD Controller

18.2.6 Static Mode

In static mode, each MSP430 segment pin drives one LCD segment and one
common line, COM0, is used. Figure 18−3 shows some example static
waveforms.

Figure 18−3. Example Static Waveforms

f

frame

COM0

SP1

SP2

Resulting Voltage for
Segment a (COM0−SP1)
Segment Is On.

COM0

SP1

SP6

SP2

SP7

SP3

SP8

SP4

SP5

V1

V5

V1

V5

V1

V5

V1

0 V

V1

0 V

SP = Segment Pin

Resulting Voltage for
Segment b (COM0−SP2)
Segment Is Off.