Timer_A Operation

12-16

Timer_A

Output ExampleTimer in Up/Down Mode

The OUTx signal changes when the timer equals TACCRx in either count
direction and when the timer equals TACCR0, depending on the output mode.
An example is shown in Figure 12−14 using TACCR0 and TACCR2.

Figure 12−14. Output Example—Timer in Up/Down Mode

0h

0FFFFh

TAIFG

Output Mode 1: Set

Output Mode 2: Toggle/Reset

Output Mode 3: Set/Reset

Output Mode 4: Toggle

Output Mode 5: Reset

Output Mode 6: Toggle/Set

Output Mode 7: Reset/Set

TACCR0

TACCR2

EQU2

TAIFG

Interrupt Events

EQU2

EQU0

EQU2

EQU2

EQU0

Note:

Switching Between Output Modes

When switching between output modes, one of the OUTMODx bits should
remain set during the transition, unless switching to mode 0. Otherwise,
output glitching can occur because a NOR gate decodes output mode 0. A
safe method for switching between output modes is to use output mode 7 as
a transition state:

BIS

#OUTMOD_7,&TACCTLx ; Set output mode=7

BIC

#OUTMODx,&TACCTLx

; Clear unwanted bits