SVS Registers

6-7

Supply Voltage Supervisor

6.3

SVS Registers

The SVS registers are listed in Table 6−1.

Table 6−1. SVS Registers

Register

Short Form

Register Type

Address

Initial State

SVS Control Register

SVSCTL

Read/write

056h

Reset with BOR

SVSCTL, SVS Control Register

7

6

5

4

3

2

1

0

VLDx

PORON

SVSON

SVSOP

SVSFG

rw−0

rw−0

rw−0

rw−0

rw−0

r

r

rw−0

Reset by a brownout reset only, not by a POR or PUC.

VLDx

Bits
7-4

Voltage level detect. These bits turn on the SVS and select the nominal SVS
threshold voltage level. See the device−specific datasheet for parameters.
0000 SVS is off
0001 1.9 V
0010 2.1 V
0011 2.2 V
0100 2.3 V
0101 2.4 V
0110 2.5 V
0111 2.65 V
1000 2.8 V
1001 2.9 V
1010 3.05
1011 3.2 V
1100 3.35 V
1101 3.5 V
1110 3.7 V
1111

Compares external input voltage SVSIN to 1.2 V.

PORON

Bit 3

POR on. This bit enables the SVSFG flag to cause a POR device reset.
0

SVSFG does not cause a POR

1

SVSFG causes a POR

SVSON

Bit 2

SVS on. This bit reflects the status of SVS operation. This bit DOES NOT turn
on the SVS. The SVS is turned on by setting VLDx > 0.
0

SVS is Off

1

SVS is On

SVSOP

Bit 1

SVS output. This bit reflects the output value of the SVS comparator.
0

SVS comparator output is high

1

SVS comparator output is low

SVSFG

Bit 0

SVS flag. This bit indicates a low voltage condition. SVSFG remains set after
a low voltage condition until reset by software.
0

No low voltage condition occurred

1

A low condition is present or has occurred