Pulse sample mode, Figure 20−4. pulse sample mode – Texas Instruments MSP430x4xx User Manual

Page 384

Advertising
background image

ADC12 Operation

20-8

ADC12

Pulse Sample Mode

The pulse sample mode is selected when SHP = 1. The SHI signal is used to
trigger the sampling timer. The SHT0x and SHT1x bits in ADC12CTL0 control
the interval of the sampling timer that defines the SAMPCON sample period
t

sample.

The sampling timer keeps SAMPCON high after synchronization with

AD12CLK for a programmed interval t

sample

. The total sampling time is t

sample

plus t

sync

. See Figure 20−4.

The SHTx bits select the sampling time in 4x multiples of ADC12CLK. SHT0x
selects the sampling time for ADC12MCTL0 to 7 and SHT1x selects the
sampling time for ADC12MCTL8 to 15.

Figure 20−4. Pulse Sample Mode

Start
Sampling

Stop

Sampling

Conversion

Complete

SAMPCON

SHI

tsample

tconvert

tsync

13 x ADC12CLK

Start
Conversion

ADC12CLK