<15. OPERATION OF SENCOM pH/ORP>

15-1

IM 12A01A02-01E

5th Edition : Oct. 31, 2013-00

15. OPERATION OF SENCOM pH/ORP

This chapter describes the screen operations of SENCOM pH/ORP, the object to be measured.
Further details of screen operations can also be found in section 1.2.

10.38

Tag:SENCOM

25.0

4mA

20mA

PH1

°C

pH

19 mV

Execute:
Calibration
HOLD

Setup:
Commissioning
Change language
Start Quick Setup

Execute & Setup

◆Sensor setup
◆Measuremet setup
◆Output setup
◆Error configuration
◆Logbook configuration
◆Advanced setup
◆Display setup

Comissioning

◆Manual
◆Automatic
◆Sample

Calibration pH

◆Manual
◆Sample

Calibration ORP

◆Zero/Slope
◆Zero/Slope/ITP(3point)
◆Zero/Slope1,2(3point)

pH Manual

◆Zero/Slope
◆Zero/Slope/ITP(3point)
◆Zero/Slope1,2(3point)

pH Automatic

◆pH
◆ORP
◆Temperature

Calibration

HART  >
PH201G >

Communication

◆Setting logbook

Logbook configuration

◆Main display
◆Trend
◆Auto Return
◆Adjust contrast
◆MONITOR display

Display setup

◆Enter values

Table mA

Change language

HOLD

Setup: Linear >
   Table >

mA(Output)

◆x-axis: Timing
◆Y-axis: Limits

Trend

◆Additional text

Main display

◆Enter values

Matrix

Input 1 impedance: Low >
Input 2 impedance: Low >

Impedance setup

◆Temperature settings
◆Temp. compensation
◆Calibration settings
◆Impedance settings
◆Concentration
◆Sensor diag. settings

Measurement setup

Compensation: Manual >
Reference temp.
 pH: Matrix

TC >
 ORP: TC >

Temp. comp.

◆Define heat cycle
◆Define SENCOM status

Sensor diag. setting

◆pH settings
◆ORP settings
◆rH settings

Cal. settings

◆Zero and Slope units
◆Limits and timing
◆Buffers (select set)
◆Zero/Slope/ITP
◆Auto correct(Zero, Slope)

Cal. set pH

Select buffer set:
  Free programmable >

Buffers

mA: Output >
  Simulate >

◆Configure Hold

Output setup

◆Settings
◆Tag
◆Passwords
◆Date/Time
◆Communication
◆Factory setup

Advanced setup

Wash contact: Enabled >

PH201G setup

◆Enter values

Buffer table 1

◆Buffer table 1
◆Buffer table 2
◆Buffer table 3

Free programmable

Quick setup

Seneor setup

Date/Time

Measurement setup

Temperature settings

mA(output)

16.1

16.2

16.3

16.4

16.5

16.6

16.7

2.7

17.1

17.3

17.2

17.1.1

17.1.2

17.1.3

17.4

16.2.2

16.2.3

16.2.4

16.2.5

16.2.6

16.2.7

16.7.1

16.7.2

16.7.3

16.7.4

16.7.5

16.6.1

16.6.2

16.6.3

16.6.4

16.6.5

16.6.6

15.2

16.6.4

16.1

16.2.1

16.2.2

16.3

Figure 15.1

Menu structure of SENCOM pH/ORP (the number after the item refers to the relevant section)