1.2 MX100 Main Module Functions

The main module is the heart of the MX100 Data Acquisition Unit. For details, see the
user’s manual (IM MX100-01E).

Ethernet port

Power switch

CF card

slot

Power connector

7-segment LED

Dipswitch*

DATA ACQUISITION UNIT

ETHERNET

POWER

10BASE - T

100BASE - TX

100 - 240V AC

Do not operate without reading safety precaution in users manual.

70VA MAX

50/60Hz

SW

ON

1 2 3 4 5 6 7 8

Functional ground terminal

* Normally all switches are ON.

Used when initializing settings

and for other purposes.

ON

1

2

3

4

5

6

7

8

Contents Displayed on the 7-Segment LED

The two-digit 7-segment LED displays the unit number, operating status, operation
complete, and operation error of the MX100 Data Acquisition Unit.

Unit Number Display

Since a single MX100 Data Acquisition Unit can be connected to a PC on the MX100
Standard Software, the unit number is fixed to 00 and displayed as

When using

MXLOGGER (software sold separately) that allows up to 20 MX100 Data Acquisition
Units to be connected, the unit number can be set in the range of 00 to 19 and dsplayed
as

to

.

Display of the Self-Test Operation at Power on

When the power is turned ON, the LED displays startup indications (such as

), and

a self-test is carried out. While the self-test is in progress, the following displays are
repeated.

Operation Mode Display

The MX100 Data Acquisition Unit has three operation modes: idle mode, measurement
mode, and backup mode (measured data saved to a CF card due to the disconnection
of communications). The modes are displayed as shown below. If the figure below,

indicates the unit number. If the unit number is not 00, the specified unit number is displayed.

• Idle mode

• Measurement mode

• Backup mode

Two zeroes

Two zeroes and a dot

Two zeroes and two dots

Display When Operation Is Complete

The figure below shows the display that appears when an operation such as IP address
configuration and measurement condition change is completed. In the figure below,

indicates the unit number. If the unit number is not 00, the specified unit number is

displayed.

Turns off

for 1 second