Sense]:frequency:start, Sense]:frequency:stop, Sense]:limit<n>:delete – GW Instek GSP-930 Programming Manual User Manual
Page 139: Sense]:jitter:offset:start

REMOTE CONTROL
137
[:SENSe]:FREQuency:STARt
Set
Query
Description
Sets or queries the start frequency.
Syntax
[:SENSe]:FREQuency:STARt <freq>
Query Syntax
[:SENSe]:FREQuency:STARt?
Parameter
<freq>
<NRf>
Return parameter <NR3>
Hz
Example
FREQ:STAR: 0
[:SENSe]:FREQuency:STOP
Set
Query
Description
Sets or queries the stop frequency.
Syntax
[:SENSe]:FREQuency:STOP <freq>
Query Syntax
[:SENSe]:FREQuency:STOP?
Parameter
<freq>
<NRf>
Return parameter <NR3>
Hz
Example
FREQ:STOP: 1.0e+6
[:SENSe]:LIMit<n>:DELete
Set
Description
Deletes the chosen limit line.
Syntax
[:SENSe]:LIMit<n>:DELete
Parameter
<n>
<NR1> limit line number
Example
:LIM3:DEL
[:SENSe]:JITTer:OFFSet:STARt
Set
Query
Description
Sets or queries the start offset for phase jitter
measurements.
Syntax
[:SENSe]:JITTer:OFFSet:STARt <freq>