Sense]:semask:offset<n>:addition: frequency:start, Sense]:semask:offset<n>:addition: frequency:stop – GW Instek GSP-930 Programming Manual User Manual

Page 150

Advertising
background image

GSP-930 Programming Manual

148

[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?

Query

Description

Returns the start frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.

Query syntax

[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?

Parameter/
Return parameter

<n>

Offset 1 to 5

<NR3>

Start frequency in Hz

Example

:SEM:OFFS1:ADD:FREQ:STAR?
>2.5e+6

[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?

Query

Description

Returns the stop frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.

Query syntax

[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?

Parameter/
Return parameter

<n>

Offset 1 to 5

<NR3>

Stop frequency in Hz

Example

:SEM:OFFS1:ADD:FREQ:STOP?
>3.5e+6

Advertising