Sense]:semask:offset<n>:frequency: start – GW Instek GSP-930 Programming Manual User Manual

Page 152

Advertising
background image

GSP-930 Programming Manual

150

Syntax

[:SENSe]:SEMask:OFFSet<n>:BANDwidth|BWIDth
[:RESolution] <freq>

Query Syntax

[:SENSe]:SEMask:OFFSet<n>:BANDwidth|BWIDth
[:RESolution]?

Parameter/
Return parameter

<freq>

<NR3> Hz

<n>

<NR1>offset 1~5

Example

SEM:OFFS1:BAND 3.0e+3

[:SENSe]:SEMask:OFFSet<n>:BANDwidth|B
WIDth[:RESolution]:AUTO

Set

Query

Description

Turns the resolution bandwidth for the selected
channel to manual or automatic mode or queries
its state.

Syntax

[:SENSe]:SEMask:OFFSet<n>:BANDwidth|BWIDth
[:RESolution]:AUTO {OFF|ON|0|1}

Query Syntax

[:SENSe]:SEMask:OFFSet<n>:BANDwidth|BWIDth
[:RESolution]:AUTO?

Parameter

0

Set RBW to manual.

1

Set RBW to auto.

OFF

Set RBW to manual.

ON

Set RBW to auto.

Return parameter 0

RBW is set to manual.

1

RBW is set to auto.

[:SENSe]:SEMask:OFFSet<n>:FREQuency:
STARt

Set

Query

Description

Sets or queries the start frequency of the selected
offset.

Syntax

[:SENSe]:SEMask:OFFSet<n>:FREQuency:STARt
<freq>

Query Syntax

[:SENSe]:SEMask:OFFSet<n>:FREQuency:STARt?

Advertising