Sense]:semask:offset<n>:frequency: stop, Sense]:semask:offset<n>:start: absolute, Sense]:semask:offset<n>:start: relative – GW Instek GSP-930 Programming Manual User Manual

Page 153

Advertising
background image

REMOTE CONTROL

151

Parameter/
Return parameter

<freq>

<NR3> Hz

<n>

<NR1>offset 1~5

Example

SEM:OFFS1:FREQ:STAR 2.5e+3

[:SENSe]:SEMask:OFFSet<n>:FREQuency:
STOP

Set

Query

Description

Sets or queries the stop frequency of the selected
offset.

Syntax

[:SENSe]:SEMask:OFFSet<n>:FREQuency:STOP
<freq>

Query Syntax

[:SENSe]:SEMask:OFFSet<n>:FREQuency:STOP?

Parameter/
Return parameter

<freq>

<NR3> Hz

<n>

<NR1>offset 1~5

Example

SEM:OFFS1:FREQ:STOP 2.5e+3

[:SENSe]:SEMask:OFFSet<n>:STARt:
ABSolute

Set

Query

Description

Sets or queries the amplitude of the start frequency
of the Absolute Mask for the selected offset.

Syntax

[:SENSe]:SEMask:OFFSet<n>:STARt:ABSolute <ampl>

Query Syntax

[:SENSe]:SEMask:OFFSet<n>:STARt:ABSolute?

Parameter/
Return parameter

<ampl>

<NR3> dBm

<n>

<NR1>offset 1~5

Example

SEM:OFFS1:STAR:ABS 1.5e+1

[:SENSe]:SEMask:OFFSet<n>:STARt:
RELative

Set

Query

Description

Sets or queries the amplitude of the start frequency
of the Relative Mask for the selected offset.

Syntax

[:SENSe]:SEMask:OFFSet<n>:STARt:RELative <ampl>

Advertising