Calculate:sem:offset<n>:result, Calculate:toi:differential – GW Instek GSP-930 Programming Manual User Manual

Page 95

Advertising
background image

REMOTE CONTROL

93

Description

Turns the SEM measurement on/off or queries its
state.

Syntax

:CALCulate:SEM:STATe {ON|OFF|1|0}

Query Syntax

:CALCulate:SEM:STATe?

Parameter

0

Turns SEM off.

1

Turns SEM on.

OFF

Turns SEM off.

ON

Turns SEM on.

Return parameter 0

SEM is off.

1

SEM is on.

Example

:CALC:SEM:STAT ON

:CALCulate:SEM:OFFSet<n>:RESult?

Query

Description

Returns the start, stop frequencies as well as the
pass/fail limits and judgements for the chosen
offset.

Query syntax

:CALCulate:SEM:OFFSet<n>:RESult?

Parameter

<n>

Offset number 1~5.

Return parameter <start freq> Start frequency of the selected channel

<low dBm> Lower dBm measurement

<low p/f>

Lower pass/fail limit judgment.
0 = pass, 1 = fail.

<stop freq> Stop frequency of the selected channel

<upp dBm> Upper dBm measurement

<upp p/f> Upper pass/fail limit judgment

0 = pass, 1 = fail.

Example

:CALC:SEM:OFFS1:RES?
>9e+7, -7.9e+1,0,1.7e+7,-6.9e+1,0

:CALCulate:TOI:DIFFerential?

Query

Description

Returns the third order intermodulation distortion.

Query syntax

:CALCulate:TOI:DIFFerential?