Sense]:ocbw:percent, Sense]:ocbw:space, Sense]:pmeter:frequency – GW Instek GSP-930 Programming Manual User Manual

Page 141

Advertising
background image

REMOTE CONTROL

139

Parameter

<freq>

<NRf>

Return parameter <NR3>

Hz

Example

:OCBW:BAND 4.5+6

[:SENSe]:OCBW:PERCent

Set

Query

Description

Sets or queries the OCBW percentage (OCBW %)
parameter.

Syntax

[:SENSe]:OCBW:PERCent <integer>

Query Syntax

[:SENSe]:OCBW:PERCent?

Parameter/
Return parameter

<integer>

<NR1>0~100

Example

:OCBW:PERC 90

[:SENSe]:OCBW:SPACe

Set

Query

Description

Sets or queries the OCBW channel space for
OCBW measurements.

Syntax

[:SENSe]:OCBW:SPACe <freq>

Query Syntax

[:SENSe]:OCBW:SPACe?

Parameter

<freq>

<NRf>

Return parameter <NR3>

Example

:OCBW:SPAC 6e+7

[:SENSe]:PMETer:FREQuency

Set

Query

Description

Sets or queries the power meter measurement
frequency.

Syntax

[:SENSe]:PMETer:FREQuency <freq>

Query Syntax

[:SENSe]:PMETer:FREQuency?

Advertising