Calculate:marker<n>:fcount: resolution:auto, Calculate:marker<n>:fcount:state – GW Instek GSP-930 Programming Manual User Manual

Page 82

Advertising
background image

GSP-930 Programming Manual

80

Example

:CALC:MARK1:FCO:RES?
>1.0e+3

:CALCulate:MARKer<n>:FCOunt:
RESolution:AUTO

Set

Query

Description

Sets the frequency counter resolution Auto setting
on/off.

Syntax

:CALCulate:MARKer<n>:FCOunt:RESolution:AUTO
{ON|OFF|1|0}

Query Syntax

:CALCulate:MARKer<n>:FCOunt:RESolution:AUTO?

Parameter

<n>

<NR1>Marker number 1~6

0

Auto is off.

1

Auto is on.

OFF

Auto is off.

ON

Auto is on.

Return parameter 0

Auto is off.

1

Auto is on.

Example

:CALC:MARK1:FCO:RES:AUTO?

:CALCulate:MARKer<n>:FCOunt:STATe

Set

Query

Description

Sets or queries the state of the frequency counter
function.

Syntax

:CALCulate:MARKer<n>:FCOunt:STATe {ON|OFF|1|0}

Query Syntax

:CALCulate:MARKer<n>:FCOunt:STATe?

Parameter

<n>

<NR1>Marker number 1~6

0

Turn frequency counter off.

1

Turn frequency counter on.

OFF

Turn frequency counter off.

ON

Turn frequency counter on.

Return parameter 0

Frequency counter is off.

1

Frequency counter is on.

Example

:CALC:MARKer1:FCO:STAT 1

Advertising