Electrical Data Free Cool Chiller Extra Quiet Continued

ELECTRICAL DATA

DCF016DX-04AJJ0

DCF018DX-04BJK0

DCF020DX-06BFK0

Unit Data

Nominal Run Amps

(1)

A

118.0

130.0

128.5

Maximum Start Amps

A

271.0

312.0

401.0

Recommended Mains Fuse Size

A

160

160

160

Mains Supply

VAC

400 V 3 PH 50 Hz

Max Mains Incoming Cable Size

mm²

Direct to Bus Bar

Recommended Permanent Fuse Size

A

16

16

16

Permanent Supply

VAC

230 V 1 PH 50 Hz

Max Permanent Incoming Cable Size

mm²

4 mm² terminals

Control Circuit

VAC

24V/230VAC

Evaporator

Pad Heater Rating

W

80

100

100

External Trace Heating

Available (fitted by others)

W

500

500

500

Condenser Fan - Per Fan (AC)

Quantity

4

4

6

Full Load Amps

A

2.5

2.5

2.5

Locked Rotor Amps

A

8.8

8.8

8.8

Motor Rating

kW

1.27

1.27

1.27

Condenser Fan - Per Fan (EC)

Quantity

4

4

6

Full Load Amps

A

3.9

3.9

3.9

Locked Rotor Amps

A

N/A

N/A

N/A

Motor Rating

kW

2.56

2.56

2.56

Compressor - Per Compressor

Nominal Run Amps

A

27.0 / 27.0

27.0 / 33.0

47.5 / 33.0

Quantity

4

2 + 2

1 + 2

Motor Rating

kW

13.7 / 13.7

13.7 / 18.8

28.2 / 18.8

Sump Heater Rating

W

75

75

130 / 75

Start Amps

A

180 / 180

180 / 215

320 / 215

Type Of Start

Direct on line

OPTIONAL EXTRAS

Power Factor Correction

Circuit 1 Comp RLA (PFC)

20.9

20.9

42.8

Circuit 2 Comp RLA (PFC)

20.9

28.5

28.5

Nominal Run Amps

A

93.4

108.7

114.8

Maximum Start Amps

A

252.6

295.2

392.0

Compressor Nominal Run Amps

A

20.9 / 20.9

20.9 / 28.5

42.8 / 28.5

Recommended Mains Fuse Size

A

160

160

160

Electronic Soft-start

Nominal Run Amps

A

118.0

130.0

128.5

Maximum Start Amps

A

199.0

226.0

273.0

Recommended Mains Fuse

A

160.0

160.0

160.0

Power Factor Correction & Electronic Soft Start

Nominal Run Amps

A

93.4

108.7

114.8

Maximum Start Amps

A

180.6

209.2

264.0

Compressor Nominal Run Amps

A

20.9 / 20.9

20.9 / 28.5

42.8 / 28.5

Recommended Mains Fuse Size

A

160

160

160

Condenser Fan - Per Fan (EC Extra Freecooling)

Quantity

N/A

N/A

N/A

Full Load Amps

A

N/A

N/A

N/A

Locked Rotor Amps

A

N/A

N/A

N/A

Motor Rating

kW

N/A

N/A

N/A

Standard Head Pump (Single or Run/Standby)

Pump Full Load Amps

A

8.9

8.9

8.9

Unit Nominal Run Amps

A

126.9

138.9

137.4

Recommended Mains Fuse Size

A

160

160

160

Motor Rating

kW

4

4

4

Larger Head Pump (Single or Run/Standby)

Pump Full Load Amps

A

11.8

11.8

11.8

Unit Nominal Run Amps

A

129.8

141.8

140.3

Recommended Mains Fuse Size

A

160

160

200

Motor Rating

kW

5.5

5.5

5.5

Standard Head Inverter Pump (Single or Run/Standby)

Pump Full Load Amps

A

6.3

8

8

Unit Nominal Run Amps

A

124.3

138.0

136.5

Recommended Mains Fuse Size

A

160

160

160

Motor Rating

kW

3

4

4

Larger Head Inverter Pump (Single or Run/Standby)

Pump Full Load Amps

A

8

11.2

11.2

Unit Nominal Run Amps

A

126.0

141.2

139.7

Recommended Mains Fuse Size

A

160

160

160

Motor Rating

kW

4

5.5

5.5

(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.