RADWAG BALANCES 3Y SERIES User Manual

Page 215

Advertising
background image

- 215 -

MASS FRAME „P1” CR LF

MASS FRAME „P2” CR LF

- immediate response of mass value in basic

measuring unit from all weighing platforms

Frame format with mass from each weighing platform:

1 2

3

4

5

6

7-15

16 17 18 19 20 21

P n space stability

marker space character mass space

unit

CR LF

Where:

n - weighing platform number

mass - 9 characters with right justification

unit - 3 characters with left justification

Example:

In case there are two weighing platforms.

S I A CR LF – command sent from a computer

P 1 _ ? _ _ _ _ _ _ 1 1 8 . 5 _ g _ _ CR LF

P 2 _ _ _ _ _ _ _ _ _ 3 6 . 2 _ k g _ CR LF - command carried out,

immediate response is mass value from both weighing platforms in basic

measuring unit specific for each of the weighing platforms.

Send stable measurement result in current weighing unit

Format: SU CR LF

Accessible responses:

SU_A CR LF

SU_E CR LF

- command understood and in progress

- time limit exceeded while waiting for stable measurement

result

SU_I CR LF

- command understood but not accessible at this moment

SU_A CR LF

MASS FRAME

- command understood and in progress

- response is mass value in current measuring unit

Frame format:

1 2

3

4

5

6

7-15

16 17 18 19 20 21

S U space stability

marker space character mass space

unit

CR LF

Example:

S U CR LF – command from a computer

S U _ A CR LF – command understood and in progress

S U _ _ _ - _ _ 1 7 2 . 1 3 5 _ N _ _ CR LF - command carried out,

response is mass value in current measuring unit.

Immediately send measurement result in current measuring unit

Format: SUI CR LF

Accessible responses:

SUI_I CR LF

- command understood but not accessible at this

moment

Advertising