Using Explicit Messaging

6-51

20-COMM-E EtherNet/IP Adapter User Manual

Publication 20COMM-UM010G-EN-P

controller. If the parameter data type is a REAL, the floating point value in
the SLC 500 controller is copied (COP) to two 16-bit integers. Then the
MSW (most significant word) and LSW (least significant word) must be
swapped before moving (MOV) the values to the array to be written to. See
the drive documentation to determine the parameter data type (32-bit integer
or REAL).

Figure 6.63 Example Ladder Logic to Copy Request Data for PowerFlex 750-Series

Drive

Parameter 780 -

[PTP Setpoint]

PowerFlex

750-Series Drives

Parameter 536 -

[Accel Time 2]