Rockwell Automation 20-COMM-E PowerFlex EtherNet/IP Adapter User Manual

Page 54

Advertising
background image

4-8

Configuring the I/O

20-COMM-E EtherNet/IP Adapter User Manual

Publication 20COMM-UM010G-EN-P

When a 32-bit parameter is selected for Input Data or Output Data for a
drive with 16-bit Datalinks, two contiguous Datalinks (for example, x1
and x2, where x = A, B, C or D) are automatically assigned as a pair to
represent that parameter. See Datalink examples in the screen shown on
the previous page. For more information on Datalinks, see

Using

Datalinks on page 5-9

.

On the Module Definition screen, notice that the automatically-assigned
controller tags DriveStatus, OutputFreq, DriveLogicRslt, and
CommandedFreq are always used.

When a Datalink is enabled, the following 20-COMM-E adapter I/O
parameters are automatically set:

– Parameter 23 - [DPI I/O Cfg] turns on the enabled Datalink bit so

the 20-COMM-E adapter will communicate that Datalink’s
information with the drive.

– Parameter 35 - [M-S Input] turns on the enabled Datalink bit so the

20-COMM-E adapter will input that Datalink’s information from the
controller.

– Parameter 36 - [M-S Output] turns on the enabled Datalink bit so

the 20-COMM-E adapter will output that Datalink’s information to
the controller.

7. Click OK on the Module Definition screen to save the drive and adapter

configuration and close the screen.

The drive’s New Module screen reappears.

Drive

Rating

The voltage and current rating of the drive. If the drive rating is not listed, the

drive database is not installed on your computer. To get the correct drive rating,

use the

Create Database, Web Update, or Match Drive button described

above.

Connection

Parameters via Datalinks. When selecting ‘Parameters via Datalinks’ (default),

the controller tags for the Datalinks use the drive parameter names to which

they are assigned. When selecting ‘Datalinks’, the controller tags for the

Datalinks have non-descriptive UserDefinedData[n] names like those used in

RSLogix 5000 software, version 15.00.

Data

Format

Parameters. When the Connection field is set to ‘Parameters via Datalinks’,

‘Parameters’ is automatically selected. When the Connection field is set to

‘Datalinks’, you must select the number of Datalinks required for your application

in the ‘Data Format’ field.

Datalink

A, B, C, D

In the Input Data column, assigns selected drive parameters to be READ by the

controller. In the Output Data column, assigns selected drive parameters to be

WRITTEN by the controller.

Sort Input/

Output

selection…

When this box is checked, sorts the Input Data and Output Data assigned

parameters by name and then by number, and enables parameter search by

name. When unchecked, sorts the assigned parameters by parameter number

and then by name, and enables parameter search by number.

Use

Network

Reference

Conveniently selects the speed reference for the drive to come from the

network. This box is checked by default.

Box