Instance attributes – Rockwell Automation 20-COMM-E PowerFlex EtherNet/IP Adapter User Manual

Page 261

Advertising
background image

EtherNet/IP Objects

C-27

20-COMM-E EtherNet/IP Adapter User Manual

Publication 20COMM-UM010G-EN-P

Instance Attributes

Attribute ID Access Rule Name

Data Type

Description

0

Get

Full/All Information

STRUCT of:

BOOL[32]

CONTAINER

(1)

CONTAINER

CONTAINER

CONTAINER

WORD

WORD

STRING[4]

WORD

WORD

WORD

INT

DWORD

STRING[16]

Descriptor (see

page C-19

)

Value

Minimum value

Maximum value

Default value

Pad Word

Pad Word

Units (for example, Amp, Hz)

Multiplier

(2)

Divisor

(2)

Base

(2)

Offset

(2)

Link (source of the value) (0 = no link)

Diagnostic name text

1

Get/Set

Value

Various

Diagnostic item value

2

Get

International Diagnostic Item Text

STRUCT of:

STRINGN

STRINGN

Diagnostic name text

Diagnostic units text

3

Get

International Full Read All

STRUCT of:

BOOL[32]

CONTAINER

CONTAINER

CONTAINER

CONTAINER

WORD

WORD

WORD

WORD

WORD

INT

DWORD

BOOL[32]

STRINGN

STRINGN

Descriptor

Value

Minimum

Maximum

Default

Pad Word

Pad Word

Multiplier

Divisor

Base

Offset

Pad

Extended descriptor

Diagnostic name text

Diagnostic units text

(1)

A CONTAINER is a 32-bit block of data that contains the data type used by a value. If signed, the value is sign extended. Padding is used in the

CONTAINER to ensure that it is always 32-bits.

(2)

This value is used in the formulas used to convert the value between display units and internal units. See

Formulas for Converting on page C-21

.

Advertising