Viewing the Adapter Web Pages

Configure E-mail Notification
Web Page

The Configure E-mail Notification web page contains selections and data fields
for configuring the adapter to automatically send email messages to desired
addresses when selected types of events occur. To view this web page, click the
‘Configure e-mail…’ link (highlighted in

Figure 35

) in the navigation pane.

Figure 35 - Example of Configure E-mail Notification Web Page

By default, settings are not protected. After configuration, settings can be
protected by using Parameter 53 - [Web Features] to set E-mail Cfg Bit 0 value
to ‘0’ (Disabled). To change a protected configuration, it must first be
unprotected by setting the E-mail Cfg Bit 0 value back to ‘1’ (Enabled).

To configure email notification, perform the following steps.

1.

Click the desired check boxes corresponding to what you want to occur
that will send email notification.

If you only want email notification when specific faults or alarms occur,
click this radio button and enter the fault or alarm numbers in the box.

If you only want email notification when all faults or alarms except
specific faults or alarms occur, click this radio button and enter the fault
or alarm numbers in the box.

2.

Click the communication fault and/or idle fault check box if you want
email notification when these faults occur.