Rockwell Automation 20G PowerFlex 755 Drive Embedded EtherNet/IP Adapter User Manual

Page 130

Advertising
background image

130

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013

Appendix B

Adapter Parameters

46
47
48
49

[Gateway Cfg 1]
[Gateway Cfg 2]
[Gateway Cfg 3]
[Gateway Cfg 4]
Sets the gateway address bytes for the adapter’s network address
when Parameter 36 - [BOOTP] is set to ‘0’ (Disabled), and the
IP Address switches (

Figure 1 on page 19

) are not being used

(that is, switches set to any value other than 001…254 or 888).

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

255

Type:

Read/Write

Reset Required:

Yes

50

[Net Rate Cfg]
Sets the speed and duplex network data rate at which the
adapter communicates. (Updates Parameter 51 - [Net Rate
Act]
after a reset.)

Default:

0 = Autodetect

Values:

0 = Autodetect
1 = 10 Mbps Full
2 = 10 Mbps Half
3 = 100 Mbps Full
4 = 100 Mbps Half

Type:

Read/Write

Reset Required:

Yes

51

[Net Rate Act]
Displays the actual speed and duplex network data rate used by
the adapter.

Values:

0 = No Link
1 = 10 Mbps Full
2 = 10 Mbps Half
3 = 100 Mbps Full
4 = 100 Mbps Half
5 = Dup IP Addr

Type:

Read Only

52

[Web Enable]
Enables/disables the adapter’s web pages.

Default:

0 = Disabled

Values:

0 = Disabled
1 = Enabled

Type:

Read/Write

Reset Required:

Yes

53

[Web Features]
Enables/disables the web-configurable email notification
feature.

Default:

xxxx xxxx xxxx xxx1

Bit Values:

0 = Disabled
1 = Enabled

Type:

Read/Write

Reset Required:

No

Parameter

No.

Name and Description

Details

255.255.255.255

[Gateway Cfg 1]

[Gateway Cfg 2]

[Gateway Cfg 3]

[Gateway Cfg 4]

Bit
Definition

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

Not Use

d

E-

mai

l C

fg

Default

x

x

x

x

x

x

x

x

x

x

x

1

Bit

15 14 13 12 …

7

6

5

4

3

2

1

0