Appendix e, History of changes, 750com-um001d-en-p, february 2012 – Rockwell Automation 20G PowerFlex 755 Drive Embedded EtherNet/IP Adapter User Manual

Page 175

Advertising
background image

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013

175

Appendix

E

History of Changes

This appendix summarizes the revisions to this manual. Reference this appendix
if you need information to determine what changes have been made across
multiple revisions. This may be especially useful if you are deciding to upgrade
your hardware or software based on information added with previous revisions of
this manual.

750COM-UM001D-EN-P,
February 2012

Topic

Page

750COM-UM001D-EN-P, February 2012

175

750COM-UM001C-EN-P, November 2011

176

750COM-UM001B-EN-P, October 2011

176

750COM-UM001A-EN-P, January 2009

176

Change

In the ‘Features’ section of Chapter 1, added new bulleted text stating that the embedded adapter supports CIP Motion
operation for the PowerFlex 755 drive (firmware 2.003 or later).

In the ‘To set up the slave (receiver) side of simple peer I/O’ section, corrected Step 3 in setting drive parameter 308 -
[Direction Mode] from ‘1’ (Bipolar) to ‘0’ (Unipolar).

In the ‘To set up the slave (receiver) side of custom peer I/O’ section:

Revised Step 7 to include an example for setting Parameter 78 - [Logic Src Cfg].
Revised Step 8 to include an example for setting Parameter 79 - [Ref Src Cfg].
Revised Step 9 to set drive parameter 308 - [Direction Mode] from ‘1’ (Bipolar) to ‘0’ (Unipolar).

At the beginning of the ‘ControlLogix Example’ section in Chapter 4, added information about where to find how to set
up CIP Motion operation.

In the ‘Using Automatic Device Configuration (ADC) with RSLogix 5000 version 20 (or later)’ section of the manual:

Added subsection ‘Version 4.01 Drive Add-On Profiles (AOPs)’.
Added subsection ‘Version 4.02 Drive Add-On Profiles (AOPs)’.
In subsection ‘Configuring a PowerFlex 755 Drive (version 4.01 or later) for ADC’, added new Step 6.
Added subsection ‘ADC and Logix Memory’.
Added subsection ‘Special Considerations When Using a DeviceLogix Program’.
Moved subsection ‘Monitoring ADC Progress’ to the end of this main section.

In Appendix B:

Changed Important statement for Parameter 89 - [To Peer Period] to say that changes to this parameter are

ignored when Parameter 91 - [To Peer Enable] is ‘1’ (On).

Changed Important statement for Parameter 90 - [To Skip Peer] to say that changes to this parameter are

ignored when Parameter 91 - [To Peer Enable] is ‘1’ (On).

In Appendix C:

At the end of the section ‘DPI Parameter Object’, in the ‘Object Specific Services’ subsection, added response data

information.

At the end of the section ‘Host DPI Parameter Object’, in the ‘Object Specific Services’ subsection, added response

data information.

Advertising