Chapter 4

Configuring the I/O

6.

Click the Port Properties icon

to open the Properties dialog box.

There are two checkboxes related to ADC.

7.

When finished, click OK.

8.

Perform all previous steps for each peripheral in the treeview on the Drive tab.
a. Select the peripheral in the treeview.

b. Click the Port Properties icon

to open the Properties dialog box.

9.

When finished configuring the drive and peripherals, click OK to close the
Module Properties dialog box for the drive.

10.

Click the Drive tab.

Checkbox Selection

Description

Enable Automatic
Device Configuration

See the Important note on

page 60

and, depending on the Drive AOP version

being used,

Version 4.01 Drive Add-on Profiles (AOPs) on page 60

or

Version 4.02

(or later) Drive Add-on Profiles (AOPs) on page 61

for additional information about

ADC use and Logix behavior. ADC is disabled when unchecked, or enabled when
checked.

Fail Drive Connection
on Peripheral Error

This selection is only available for peripherals. If you want to ensure that the
correct peripheral is present with the correct configuration before the controller
connects to the drive, check this box. If the peripheral is not essential to your use of
the drive (for example, a HIM that may or may not be present all the time),
uncheck this box. Note that when a failure occurs, RSLogix software will show
both a configuration on Port 0 (drive) and Port ‘xx’ (peripheral) error.

TIP

When using version 4.01 Drive AOPs, skip to step 13.