Setting the time zone, Setting daylight saving time – Dell PowerVault ML6000 User Manual

Page 108

Advertising
background image

Chapter 5 Configuring Your Library

Setting the Date, Time, and Time Zone

Dell PowerVault ML6000 User’s Guide

108

Details on NTP settings include:

• NTP servers must be configured in available in groups of 3 or more,

with one exception: a single NTP server configuration is also allowed.

• NTP is enabled on the

Date & Time

screen. When NTP is enabled, you

cannot manually configure date and time. For more information on

setting date and time manually, see

Setting the Date and Time

Manually

on page 107.

• You can enter an IP address for a primary and an alternate (optional)

NTP server.

• NTP server IP addresses must be entered in the proper format. See

Modifying Network Settings

on page 63 for the proper format of IPv4

and IPv6 addresses.

• After you apply NTP settings, system clock synchronization may take

several minutes.

You can only enable and configure NTP on the Web client. The path to

open the appropriate screen is as follows:

• From the Web client, select

Setup > Date & Time

.

Setting the Time Zone

5

To select your time zone from a list, disable

Use Custom Time Zone

setting

and select your time zone.
If your time zone does not appear on the list, or you want more control

over your time settings, enable

Use Custom Time Zone

and set a Universal

Coordinated Time (UTC) offset.
You can only set the time zone on the Web client. The path to open the

appropriate screen is as follows:

• From the Web client, select

Setup > Date & Time

.

Setting Daylight Saving

Time

5

If you selected your time zone from the drop-down list (see

Setting the

Time Zone

), the library automatically adjusts for daylight saving time.

There is no need to manually reset the clock for time changes.
However, if you set a custom time zone, the library will not automatically

adjust for daylight saving time. You must enable the

Use Custom Daylight

Saving Time

setting. Once enabled, you can set start and stop times to an

accuracy of one minute.

Advertising