Chapter 5 Configuring Your Library

Managing the Network

Dell PowerVault ML6000 User’s Guide

69

The paths to open the appropriate screens are as follows:

• From the Web client select

Setup > Network Management > SNMP

.

• From the operator panel select

Tools > System Settings > Enable

SNMP V1/V2

.

Choosing SNMP Trap Versions

5

The library supports SNMP v1 and v2 traps as defined by RFC 1157 (v1 is

the default). Administrators can choose which version the library uses to

report traps (v1 is the default)
The timeout for all SNMP requests to the library must be at 10 seconds or

greater (command line parameter-t).
The path to open the appropriate screen is as follows:

• From the Web client select

Setup > Network Management > SNMP

.

Modifying the SNMP Community String

5

Administrators can modify the SNMP community string. The SNMP

community string is a text string that acts as a password to authenticate

GET and GET-NEXT SNMP v1 and SNMP v2c messages exchanged

between the library and an external management application. The SNMP

community string used by the library must match the string used by the

external management application.
The default SNMP community string on the library is:

publicCmtyStr

. For

security purposes, this string should be modified. When modifying the

community string, adhere to the following guidelines: the community

string is case-sensitive, cannot be empty, and cannot exceed 32 characters.
See the Dell PowerVault ML6000 Basic SNMP Reference Guide for further

configuration and access details.
You cannot modify the SNMP community string from the operator panel.
The path to open the appropriate screen is as follows:

• From the Web client select

Setup > Network Management > SNMP

.