Dell PowerVault ML6000 User Manual
Page 427
Appendix A Library Specifications
Library Power Consumption and Heat Output
Dell PowerVault ML6000 User’s Guide
427
Library Configuration
Typical Power
Consumption
(kW/Hour)
Typical Heat
Output
(BTU/Hour)
Subassembly Power Consumption:
PowerVault ML6000 Library with Robot and LCB (no tape drives
installed; robot moving; LCB installed)
0.079
269.0
LTO-3 Drive Sled Module (SCSI)
0.027
92.1
LTO-3 Drive Sled Module (Fibre Channel)
0.029
99.0
LTO-4 Drive Sled Module (Fibre Channel)
0.040
136.5
LTO-4 Drive Sled Module (SAS)
0.038
129.7
LTO-5 Drive Sled Module (Fibre Channel)
0.048
163.8
LTO-5 Drive Sled Module (SAS)
0.046
157.0
LTO-6 Drive Sled Module (Fibre Channel)
0.034
116.0
LTO-6 Drive Sled Module (SAS)
0.032
109.2
Fibre Channel I/O Blade
0.080
272.8
Control Module:
Minimum (no drives installed; robot not moving)
0.047
160.0
Maximum (2 drives writing; robot moving)
0.166
565.0
Expansion Module:
Minimum (no drives installed; robot not moving)
0.012
41.0
Maximum (4 drives writing; 2 Fibre-Channel I/O blades
installed; robot moving)
0.256
879.0