Chapter 12 Installing, Removing, and Replacing

Replacing the 5U Library Control Module

Dell PowerVault ML6000 User’s Guide

297

10

Import tape cartridges to the correct library partitions as needed.

11

Save the library configuration (see

Saving the Library Configuration

on page 385.

12

If the host application inventories the location of each tape cartridge

in the library, open the host application and reinventory in order to

sync its logical inventory with the physical inventory of the library.

Due to the way the library logically addresses its tape drives and slots

internally, permanently removing an expansion module from the

library will change the element addresses, and this can affect proper

communication to a controlling host. See

Understanding Logical

Element Addressing

on page 38. Because of this, you must refresh the

configuration of any backup application that manages the library to

reflect the adjusted positions. In addition, you may need to reboot

the host server(s) or rescan the bus to detect the changes.

Replacing the 5U Library Control Module

These instructions explain how to remove a 5U Library Control Module

and replace it with a 5U Library Control Module field replaceable unit

(FRU). You may need to replace the 5U Library Control Module if its

chassis is severely damaged. Typically, however, only certain customer

replaceable units (CRUs) or FRUs within the 5U Library Control Module

need to be replaced.
There are some configuration settings to take into account when

replacing the 5U Library Control Module.

• If you have applied one or more license keys to the original 5U

Library Control Module, you will need to replace each license key

and apply it to the new 5U Library Control Module. For more

information, see

Obtaining and Installing a License Key

on page 88.

• A partition with all resources in the removed module will be present

with no slots or drives. This partition can only be deleted.

There are no restrictions on where the 5U Library Control Module can be

installed in the library configuration. However, the recommended

placement of the 5U Library Control Module for library configurations

up to 32U is on top of all installed 9U Library Expansion Modules. The