Chapter 12 Installing, Removing, and Replacing

Installing the Library in a Rack

Dell PowerVault ML6000 User’s Guide

344

Installing the Bottom
Module in the Rack

12

Required parts:

Rack ears, (4) M5 thumbscrews

Explanation of parts:

Each rack ear contains two elongated holes, enabling

you to fasten it to the rack (using the M5 thumbscrews) in the most

accessible mounting holes.

1

Place the desired module (whichever module you want to be the

bottom module of the library) onto the rack-mount shelves. From the

front of the rack, lift the module onto the shelf and gently slide it into

the rack. Slide the module to the back of the rack, so that the front of

the module is flush with the mounting holes.

2

From the back of the rack, secure the module to the rack-mount

shelves by tightening the two silver thumbscrews that are attached to

the rear of the rack-mount shelves.

3

Install the right rack ear. At the front of the library:

a

Open the I/E station door. At the lower right corner of the

module is a vertical slot. Insert the hinge of the right rack ear into

the slot and then position the holes of the rack ear flush with the

rack rail.

1

Hinge of rack ears