Drive diagnostics, Drive tests, Drive reset – Dell PowerVault ML6000 User Manual

Page 411

Advertising
background image

Chapter 13 Troubleshooting

Drive Diagnostics

Dell PowerVault ML6000 User’s Guide

411

Drive Diagnostics

Drive diagnostics are separated into the following categories:

Drive Tests

— Does not require you to use a scratch tape.

Media Tests

— Requires you to insert a scratch tape in the top I/E

station slot to perform the test.

Drive Tests

13

The Drive Tests currently include only one test, the Drive Reset

operation.

Drive Reset

13

The Drive Reset operation power cycles the tape drive while the tape

drive remains in the drive sled in the library. You may want to perform a

reset if a tape drive does not come ready or it is not behaving properly

(for example, if a tape is stuck in the drive and will not unload).
After the reset operation completes, the tape drive is rebooted and

reconfigured. This takes about 60 seconds. Wait 60 seconds before

performing further drive operations.

The paths to open the appropriate screens are as follows:

• From the Web client, select

Tools > Diagnostics

, then select

Drives >

Drive Tests > Drive Reset

.

• From the operator panel, select

Tools > Drive Mgmt > Reset drives

.

Note:

This operation should not be performed concurrently by

multiple administrators. You can access the screen, but you

cannot apply changes while another administrator is

performing the same operation.

Advertising