Recommended library cabling for fc i/o blades – Dell PowerVault ML6000 User Manual

Page 234

Advertising
background image

Chapter 12 Installing, Removing, and Replacing

Cabling the Library

Dell PowerVault ML6000 User’s Guide

234

c

Replace the module terminator in the 9U Library Expansion

Module terminator connection furthest from the 5U Library

Control Module.

10

Connect the module-to-module cable from the 5U Library Control

Module to the 9U Library Expansion Module.

11

Connect an Ethernet cable to the Gigabit (GB) Ethernet port on the

Library Control Blade (LCB) for remote access to the library via the

Web client.

12

Connect a power cord to the outlet on the power supply on the rear of

the library.
There should always be a power cord connected to the power supply

on the 5U Library Control Module. If redundant power supplies are

used, connect a power cord to each of the additional power supply

outlets.

13

Power on the library.

a

Turn on the rear power switch of each of the power supplies.

b

Turn on the front power button.

c

Power up the host system.

14

Verify communication with all devices on the bus.

15

Configure the library using the commands on the operator panel. See

configuration information in

Configuring Your Library

on page 56.

Recommended Library
Cabling for FC I/O Blades

12

Fibre optic cables connect Fibre Channel tape drives to FC I/O blades and

FC I/O blades to a Storage Area Network (SAN) fabric or host. Correctly

managing these cables on the rear of the library can prevent damage to

the cables and Fibre Channel ports and ensure optimal data throughput.

Ideally, an installed tape drive should be cabled to a port on the nearest

FC I/O blade to eliminate the need to manage excessively long cables.

Note:

This section applies to libraries containing Fibre Channel tape

drives, which are connected to a host or a Fibre Channel

switch using an FC I/O blade. For tape drives that are directly

attached to a host or a SAN switch, follow standard fibre optic

cable handling best practices.