Special function 8, Age 100 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 100

Advertising
background image

100

Operating Instructions – MOVIMOT® MM03C - MM3XC

8

Selectable special functions MM..C-503-30

Startup with Integrated AS-Interface

Special function 8

MOVIMOT

®

with minimum frequency 0 Hz

Function descrip-
tion

If switch f2 is in position of rest 0, the setpoint f2 measures 0 Hz with activated special
function. All other adjustable values remain unchanged.

51866AXX

6

7

8

5

2

1

ON

S4

4

5

6

3

Switch f2

Detent position

0

1

2

3

4

5

6

7

8

9

10

Setpoint f2 [Hz]
with activated special function

0

7

10

15

20

25

35

50

60

70

100

Setpoint f2 [Hz]
without special function

5

7

10

15

20

25

35

50

60

70

100

3

4

5
6

7

8

0

0

I

Advertising