Status led, 2 diagnostics of movimot, With integrated as-interface – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 132

Advertising
background image

132

Operating Instructions – MOVIMOT® MM03C - MM3XC

10

Diagnostics of MOVIMOT® with integrated AS-Interface

Diagnostics

10.2

Diagnostics of MOVIMOT

®

with integrated AS-Interface

Status LED

The status LED and the AS-i LED are located on the top of the MOVIMOT

®

inverter (see

the following figure).

Meaning of the
AS-i LED states

51870AXX

[1] AS-i LED
[2] MOVIMOT

®

status LED

[1]

[2]

LED
color

LED status

Operational status

Description

Off

Not ready

24 V missing at AS-i connection

Green

On

Ready

Normal operation
24 V present at AS-i connection
Communication present

Red

On

Not ready

Communication is faulty or slave address 0 is set

Advertising