Special function 7 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 66

Advertising
background image

66

Operating Instructions – MOVIMOT® MM03C - MM3XC

7

Selectable special functions MM..C-503-00

Startup of Standard Design

Special function 7

MOVIMOT

®

with rapid start/stop

Function descrip-
tion

The pre-magnetization time is fixed at 0 s, independent of whether MOVIMOT

®

is

operated in bus or terminal mode.

No pre-magnetization is carried out at the start of the release to begin the accelera-
tion at the setpoint ramp as quickly as possible.

The subsequent behavior of MOVIMOT

®

is dependent on the operating mode and

whether a mechanical brake is connected.

05602AXX

1

6

7

8

5

4

3

2

ON

S2

6

7

8

5

Special function 7

Rapid start/stop

Operating mode

Bus opera-

tion

Terminal

operation

Mechanical brake con-
trolled by...

...MOVIMOT

®

...relay out-

put

...MOVIMOT

®

...relay out-

put

Relay function

Ready relay

Brake relay

(see page

75)

Ready relay

Brake relay

(see page

75)

0

0

I

Advertising