Diagnostics of MOVIMOT® with integrated AS-Interface

Diagnostics

Meaning of the sta-
tus LED states

The three-color LED signals the operating and fault states.

LED
color

LED status

Operational status

Description

Off

Not ready

No 24 V power supply

Yel-
low

Steady flashing

Not ready

Self-test phase active or 24 V power supply present
but supply voltage not OK

Yel-
low

Steady, fast flashing

Ready

Releasing the brake without active drive enable
(only with S2/2 = "ON")

Yel-
low

Steady light

Ready,
but unit is inhibited

24 V power supply and supply voltage OK,
but no enable signal

Green
/yel-
low

Flashing with alter-
nating colors

Ready,
but timeout

Faulty communication with cyclical data exchange

Green

Steady light

Unit enabled

Motor in operation

Green

Steady, fast flashing

Current limit active

Drive has reached the current limit

Red

Steady light

Not ready

Check the 24 V

DC

supply.

Make sure that there is a smoothed DC voltage with
low ripple (residual ripple max. 13%) present.

Red

2 x flash, pause

Fault 07

DC link voltage too high

Red

Flashing slowly

Fault 08

Fault speed monitoring (only with S2/4="ON")

Fault 90

Assignment of motor – inverter incorrect
(e.g. MM03 – DT71D4

Ħ

)

Fault 17 to 24, 37

CPU fault

Fault 25, 94

EEPROM error

Red

3 x flash, pause

Fault 01

Overcurrent of output stage

Fault 11

Excessive temperature in output stage

Red

4 x flash, pause

Fault 84

Excessive temperature in motor
Assignment of motor to frequency inverter incorrect

Red

5 x flash, pause

Fault 89

Excessive temperature in brake
Assignment of motor to frequency inverter incorrect

Red

6 x flash, pause

Fault 06

Mains phase fault