8

Description of the DIP switches S3

Startup with Integrated AS-Interface

DIP switch S3/5

Motor type

With IEC and NEMA motors, DIP switch S3/5 must always be set to OFF, for Brazilian
motors to ON.

DIP switch S3/6

Releasing the brake without enable

With activated switch S3/6 = "ON", the brake can also be released if no drive enable is
present.

Operation with
braking resistor

The special function is not in effect if operated with braking resistor.

Releasing the
brake

The brake can be released under the following conditions by setting the AS-i bit "speed
f1/speed f2":

Setpoint selection

Setpoint selection dependent on AS-i bit "speed f1/speed f2":

Behavior with a
non-operating unit

In case of a non-operating unit, the brake is always applied independent of the setting
of AS-i bit "speed f1/speed f2".

LED display

The yellow LED display flashes periodically and quickly (t

on

: t

off

= 100 ms : 300 ms) if

the brake was released for manual procedure.

Status of
AS-i bit

Enable condition

Fault condi-
tion

Brake function

D0
(R)

D1
(L)

D2
(f1/f2)

"1"
"0"

"0"
"1"

"0"

Unit enabled

No
Unit fault

Brake is controlled by MOVIMOT

®

,

setpoint f1

"1"
"0"

"0"
"1"

"1"

Unit enabled

No
Unit fault

Brake is controlled by MOVIMOT

®

,

setpoint f2

"1"
"0"

"1"
"0"

"0"

Unit not
enabled

No
Unit fault

Brake closed

"1"

"1"

"1"

Unit not
enabled

No
Unit fault

Brake closed

"0"

"0"

"1"

Unit not
enabled

No
Unit fault

Brake released for manual procedure

All conditions possi-
ble

Unit not
enabled

Unit fault

Brake closed

Bit D3 (Reset/Controller enable) must be set to enable the drive.

Enable condition

AS-i bit

Active setpoint

Unit enabled

D2 = "0"

Setpoint potentiometer f1 active

Unit enabled

D2 = "1"

Setpoint potentiometer f2 active

0

0

I