Selectable special functions MM..C-503-30

Startup with Integrated AS-Interface

Special
function 10

MOVIMOT

®

with reduced torque at low frequencies

Function descrip-
tion

The drive builds up only a reduced torque due to a reduction in slip and active current
at low speeds (see following figure):

Minimum frequency = 0 Hz (see special function 8 on page 68)

Special
function 11

Deactivation of phase fault control

Function descrip-
tion

Phase control does not take place if the special function is activated.

This is meaningful, for example, for supply systems with brief asymmetry.

51868AXX

6

7

8

5

2

1

ON

S4

4

5

6

3

50907AXX

[1] Maximum torque with VFC operation
[2] Maximum torque with activated special function