Sample message, Ac motor. movimot, Speed [%] setpoint = 50% (from f – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 126: Po3: 0bb8, Ramp = 3 s request message from movimot

Advertising
background image

126

Operating Instructions – MOVIMOT® MM03C - MM3XC

9

Function with RS-485 master

Startup with Communications Interface / Fieldbus

Sample message

This example deals with the control of a MOVIMOT

®

AC motor using the process data

words of PDU type 85

hex

(3 PD acyclical). The RS-485 master sends three process out-

put data (PO) to the MOVIMOT

®

AC motor. MOVIMOT

®

responds with three process

input data words (PI).

Request message
from RS-485 mas-
ter to MOVIMOT

®

PO1: 0006

hex

Control word 1 = Enable

PO2: 2000

hex

Speed [%] setpoint = 50% (from f

max

)

1)

)

PO3: 0BB8

hex

ramp = 3 s

Request message
from MOVIMOT

®

RS-485 master

PI1: 0406

hex

Status word 1

PI2: 0300

hex

Output current [% IN]

PI3: 0607

hex

Status word 2

Coding of process data see section 5.5.

"3PD acyclical" sample message

This example shows acyclical transmission, i.e. no timeout monitoring is active in
MOVIMOT

®

. Cyclical transmission can be implemented with the entry TYPE = 05

hex

. In

this case, MOVIMOT

®

expects the next bus activity (request message of the aforemen-

tioned types) within one second at most, otherwise MOVIMOT

®

automatically brings it-

self to a stop (timeout monitoring).

1) f

max

is preset using f1 setpoint potentiometer

05079AEN

TYP

TYP

ADR

ADR

SD1

SD1

BCC

BCC

MOVIMOT

®

Idle

Idle

02

hex

01

hex

85

hex

00

hex

06

hex

20

hex

00

hex

0B

hex

B8

hex

13

hex

1D

hex

01

hex

85

hex

04

hex

07

hex

03

hex

00

hex

06

hex

07

hex

98

hex

TYP

TYP

ADR

ADR

SD1

SD1

BCC

BCC

MOVIMOT

®

Idle

Idle

02

hex

01

hex

85

hex

00

hex

06

hex

20

hex

00

hex

0B

hex

B8

hex

13

hex

1D

hex

01

hex

85

hex

04

hex

07

hex

03

hex

00

hex

06

hex

07

hex

98

hex

RS-485 Master

PO1: Control word
0006

= Enable

hex

PI1: Status word 1

PO2: Speed[%]
2000

= 50% f

hex

max

PI2: Output current

PO3: Ramp
0BB8

= 3s

hex

PI3: Status word 2

Process Output Data (PO)

Process Input Data (PI)

0

0

I

Advertising