Operating options mbg11a and mlg11a, 0ff 0 0 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 81

Advertising
background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

81

7

Startup with options MBG11A or MLG11A

Startup of Standard Design

Operating options MBG11A and MLG11A

Function

Explanation

Display

Negative display value e.g.:

= Counterclockwise rotation

Positive display value e.g.:

= Clockwise rotation

The displayed value indicates the speed set with the setpoint potentiometer f1. Example: Dis-
play "50" = 50 % of the speed set with setpoint potentiometer.
Important: If the display is "0," the drive is turning at f

min

.

Increasing the speed

With CW rotation:

With CCW rotation:

Reducing the speed

With CW rotation:

With CCW rotation:

Blocking MOVIMOT

®

Press the following keys simultaneously:

Display =

Enable MOVIMOT

®

or

Important: After release, MOVIMOT

®

accelerates to the value and direction of rotation

saved last.

Change in direction of
rotation from CW to
CCW

1.

Until display =

2. Pressing it again

changes direction of rotation from CW to CCW.

Change in direction of
rotation from CCW to
CW

1.

Until display =

2. Pressing it again

changes direction of rotation from CCW to CW.

Memory function

After the power supply system has been switched off and on again, the value last set is
retained provided the 24 V supply was present for at least 4 seconds following the most
recent setpoint change.

50

50

+

0FF

0

0

0

0

I