4 description of the dip switches s2, Dip switches     s2/1, Dip switches     s2/2 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 55: Description of the dip switches s2

Advertising
background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

55

7

Description of the DIP switches S2

Startup of Standard Design

7.4

Description of the DIP switches S2

DIP switches
S2/1

Motor type

With IEC and NEMA motors, DIP switch S2/1 must always be set to OFF!

With DZ motor with rated voltages of 220/380 V, 60 Hz (only available in Brazil), the
DIP switch must always be set to ON.

DIP switches
S2/2

Releasing the brake without enable

With activated switch S2/2 = "ON", the brake can also be released if no drive enable is
present.

Operation with
braking resistor

The special function is not in effect if operated with braking resistor.

Function with ter-
minal control
(address = 0)

With terminal control, the brake can be released by setting terminal f1/f2 if the following
requirements exist:

Functions in bus
operation

In bus operation, the brake is released through control in the control word.

Terminal condi-
tion

Enable condition

Fault condi-
tion

Brake function

R

L

f1/f2

"1"
"0"

"0"
"1"

"0"

Unit enabled

No
Unit fault

Brake is controlled by MOVIMOT

®

,

setpoint f1

"1"
"0"

"0"
"1"

"1"

Unit enabled

No
Unit fault

Brake is controlled by MOVIMOT

®

,

setpoint f2

"1"
"0"

"1"
"0"

"0"

Unit not
enabled

No
Unit fault

Brake closed

"1"

"1"

"1"

Unit not
enabled

No
Unit fault

Brake closed

"0"

"0"

"1"

Unit not
enabled

No
Unit fault

Brake released for manual procedure

All conditions pos-
sible

Unit not
enabled

Unit fault

Brake closed

52117AXX

PO = Process output data

PI = Process input data

PO1 = Control word

PI1 = Status word 1

PO2 = Speed (%)

PI2 = Output current

PO3 = Ramp

PI3 = Status word 2

DO = Digital outputs

DI = Digital inputs

MOVIMOT

®

PO1

PO2

PO3

DO

Master

-+

PI1

PI2

PI3

DI

PO

PI

0

0

I

Advertising