Mwa21a, Mdg11a, Bgm brake rectifier – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 152

Advertising
background image

152

Operating Instructions – MOVIMOT® MM03C - MM3XC

12

Technical data of options

Technical Data of Standard Design

MWA21A

MDG11A

BGM brake recti-
fier

Important: The brake coil must correspond to the supply voltage

MWA21A option

Part number

823 006 4

Input voltage

24 V

DC

±

25 %

Current consumption

approx. 70 mA

Serial interface

1)

1) with integrated dynamic terminating resistor

RS-485 for connecting max. 31 MOVIMOT

®

inverters

(max. 200 m, 9600 baud)
Unidirectional communication
Cycle time: 100 ms

Analog input

0...10 V / 2...10 V, R

i

12 k

0...20 mA / 4...20 mA, R

i

22

Setpoint resolution of the analog input

8 bit (

±

1 bit)

Signal level of binary inputs

+13 V...+30 V = '1'
- 3 V ...+5 V = “0”

Enclosure

IP 20

Ambient temperature

-15...60 °C

MDG11A option

Part number

822 941 4

Input voltage

24 V

DC

±

25 %

Current consumption

approx. 70 mA

Serial interface

RS-485 for connection of one MOVIMOT

®

inverter with

control via terminals

Enclosure

IP 65

Ambient temperature

-15...60 °C

BGM brake rectifier

Part number

827 602 1

Enclosure

IP20

Rated supply voltage
(black connecting leads)

230 V

AC

...500 V

AC

, +10% / -15%

50 Hz...60 Hz,

±

5%

Control voltage
(red / blue connecting leads)

+13 V...+30 V = "1“
-3 V...+5 V = "0“

Brake current
(brake connection 13, 14, 15)

max. 0.8 A

DC

Ambient temperature

-25...60 °C

P

i

f

kVA

Hz

n

Advertising