UL design with connection voltages 380500 VAC

Technical Data of Standard Design

12.2

UL design with connection voltages 380500 V

AC

MOVIMOT

®

type

MM 03C-

503-00

MM 05C-

503-00

MM 07C-

503-00

MM 11C-

503-00

MM 15C-

503-00

MM 22C-

503-00

MM 30C-

503-00

MM 3XC-

503-00

Part number

824 115 5

824 116 3

824 117 1

824 118 X

824 119 8

824 120 1

824 121 X

824 180 5

Apparent output power at
V

mains

= 380...500 V

AC

P

rated

1.1 kVA

1.4 kVA

1.8 kVA

2.2 kVA

2.8 kVA

3.8 kVA

5.1 kVA

6.7 kVA

Connection voltages
Permitted range

V

mains

3 x 380 V

AC

/ 400 V

AC

/415 V

AC

/460 V

AC

/500 V

AC

V

mains

= 380 V

AC

-10 % ... 500 V

AC

+10 %

Supply frequency

f

mains

50 Hz ... 60 Hz

±

10 %

Rated system current
(at V

mains

= 460 V

AC

)

I

mains

1.1 A

AC

1.4

A

AC

1.7

A

AC

2.1

A

AC

3.0

A

AC

4.3 A

AC

5.8 A

AC

7.5 A

AC

Output voltage

V

out

0...V

in

Output frequency
Resolution

Operating point

f

out

2...100 Hz
0.01 Hz
460 V at 60 Hz

Rated output current

I

rated

1.6 A

AC

2.0

A

AC

2.5

A

AC

3.2

A

AC

4.0

A

AC

5.5 A

AC

7.3 A

AC

9.6 A

AC

Motor power

P

mot

0.5 HP

0.37 kW

0.75 HP

0.55 kW

1.0 HP

0.75 kW

1.5 HP

1.1 kW

2 HP

1.5 kW

3.0 HP

2.2 kW

5 HP

3.7 kW

5.4 HP

1)

4 kW

1) Only possible with S3 25 % ED

PWM frequency

4 (factory setting) / 8 / 16

2)

kHz

2) 16 kHz PWM frequency (low-noise): When DIP SWITCH S1/7 = ON, the units operate with a 16 kHz PWM frequency (low noise) and

switch back in steps to lower switching frequencies depending on the heat sink temperature.

Current limitation

I

max

Motor: 160 % with

Regenerative:160 % with

Maximum motor lead
length

15 m when mounting the MOVIMOT

®

frequency inverter close to the motor

(with SEW hybrid cable and option P2.A)

External braking resistor

R

min

150

68

Interference immunity

Meets EN 61800–3

Interference emission

Meets EN 61800–3 and class A limit to EN 55011 and EN 55014

Ambient temperature

ϑ

amb

-25 °C...40 °C (P

rated

reduction: 3 % I

N

per K to max. 60 °C)

3)

3) -25 °C...40 °C with S3 25% ED (up to 60 °C with S3 10 % ED)

Climate class

3 K3

Enclosure
(motor-dependent)

IP54, IP55, IP65, IP66 (options, specify when ordering)
IP67 (only available for inverters with terminal box)

Operating mode

DB (EN 60149-1-1 and 1-3), S3 max. cycle duration 10 minutes

Cooling type (DIN 41 751)

Self-cooling

Altitude

h

1000 m (P

rated

reduction: 1 % per 100 m starting at an altitude of 1000 m, see also the section

"Electrical Installation – Installation Instructions")

Ext. power supply to elec-
tronics

Tl. 24 V

V = +24 V

±

25 %, EN 61131-2, residual ripple max. 13 %

I

in

250 mA (typ. 150 mA at 24 V)

Input capacitance 100

µ

F

Three binary inputs

Isolated by opto-coupler, PLC-compatible (EN 61131-2)
R

i

3.0 k

, I

in

10 mA, sampling time

5 ms

Signal level

+13 V...+30 V = "1" = Contact closed
-3 V...+5 V = "0" = Contact open

Control functions

Tl. R
Tl. L
Tl. f1/f2

CW/Stop
CCW/Stop
"0" = Setpoint 1 / "1" = Setpoint 2

Output relay
Contact data

Tl. K1a
Tl. K1b

Response time

15 ms

24 V

DC

/ 0.6 A

DC

/ DC11 to IEC 337-1

Signaling function

Normally open contact for ready
signal

Contact made:
– with applied voltage (24 V + supply)
– if no fault was detected
– after self-test phase concluded (after switch-on)

Serial interface

Tl. RS+
Tl. RS-

RS-485

P

i

f

kVA

Hz

n