Inverter response
according to the
terminal level

Legend

0 = No voltage

1 = Voltage

X = Any

Network

24 V

f1/f2

CW/Stop

CCW/Stop

Status LED

Inverter

behavior

0

0

x

x

x

Off

Inverter off

1

0

x

x

x

Off

Inverter off

0

1

x

x

x

Flashing

yellow

Stop, supply sys-

tem missing

1

1

x

0

0

Yellow

Stop

1

1

0

1

0

Green

Clockwise with f1

1

1

0

0

1

Green

Counterclock-

wise with f1

1

1

1

1

0

Green

Clockwise with f2

1

1

1

0

1

Green

Counterclock-

wise with f2

1

1

x

1

1

Yellow

Stop

0

0

I