Operating Instructions – MOVIMOT® MM03C - MM3XC

119

9

Coding of process data

Startup with Communications Interface / Fieldbus

9.2

Coding of process data

The same process data information is used for controlling and selecting setpoints for all
fieldbus systems. The process data are coded using the uniform MOVILINK

®

profile for

SEW drive inverters. In the case of MOVIMOT

®

, it is always possible to differentiate be-

tween the following variants:

Two process data words (2 PD)

Three process data words (3 PD)

Two process data
words

In order to control MOVIMOT

®

using two process data words, the process output data

"Control word 1" and "Speed [%]" are send to the master programmable controller for
MOVIMOT

®

; the process input data "Status word 1" and "Output current" are sent from

MOVIMOT

®

to the programmable controller.

Three process
data words

When control takes place with three process data words, 'Ramp' is sent as additional
process output data word; "Status word 2" is sent as third process input data word.

51334AXX

PO = Process output data

PI = Process input data

PO1 = Control word

PI1 = Status word 1

PO2 = Speed (%)

PI2 = Output current

PO3 = Ramp

PI3 = Status word 2

MOVIMOT

®

PO1

PO2

PO3

Master

PI1

PI2

PI3

PO

PI