background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

139

10

Diagnostics of MOVIMOT® with integrated AS-Interface

Diagnostics

Window area of MOVIMOT

®

display values

The inverter status window area displays the current device status. The following exam-
ple shows that the device is operational, the output stage is enabled and manual oper-
ation is active. The operating status is shown in plain text.

If a device fault is present, it is indicated by a red "Malfunction/warning" symbol, and the
cause is displayed in the "Operating state" field.

Process values window area

The process values window area displays the current output current (r.m.s. value),
speed, heat sink temperature, DC link voltage and information about the firmware part
number and the unit type.