Operating Instructions – MOVIMOT® MM03C - MM3XC

10

Diagnostics of MOVIMOT® standard design

Diagnostics

Diagnostics via
MDG11A option

The diagnostic unit cannot be used in conjunction with MOVIMOT

®

with integrated

AS-Interface.

The diagnostic unit must be connected prior to the possible occurrence of a fault, as
MOVIMOT

®

error messages are not saved and the information is lost when the 24 V

supply is disconnected.

The diagnostic unit may only be connected to a MOVIMOT

®

unit.

Connecting the MDG11A to an RS-485 bus with several MOVIMOT

®

is not allowed.

The diagnostic unit can be used only if the MOVIMOT

®

is controlled via terminals.

This requires that DIP switches S1/1 to S1/4 are set to OFF (= address 0).

Do nut use the diagnostic unit in case setpoint setting takes place via the
RS-485 interface.

Connection according to section "Electrical Installation."