Operating Instructions – MOVIMOT® MM03C - MM3XC

71

7

Selectable special functions MM..C-503-00

Startup of Standard Design

Special function
10

MOVIMOT

®

with reduced torque at low frequencies

Function descrip-
tion

The drive builds up only a reduced torque due to a reduction in slip compensation
and active current at low speeds (see the following figure):

Minimum frequency = 0 Hz (see special function 8 on page 68).

Special
function 11

Deactivation of phase fault control

Function descrip-
tion

Phase control does not take place if the special function is activated.

This is meaningful, for example, for supply systems with brief asymmetry.

05606AXX

1

6

7

8

5

4

3

2

ON

S2

6

7

8

5

50907AXX

[1] Maximum torque with VFC operation
[2] Maximum torque with activated special function

M

5

[1]

[2]

10

15

f [Hz]

06378AXX

1

6

7

8

5

4

3

2

ON

S2

6

7

8

5

0

0

I

Advertising