Operating Instructions – MOVIMOT® MM03C - MM3XC

39

6

Connection options with integrated AS-Interface

Electrical Installation with Integrated AS-Interface

6.2

Connection options with integrated AS-Interface

Mains and control

A

Design with AVSK plug (1 x M12 connector):

Design

A1

A2

Type designation

MM../AVSK

MM../AVSK

Switch S5

0

1

24 V supply

Yellow AS-i cable

Black AUX-PWR cable
(double tap)

AS-i connection

Yellow AS-i cable

Yellow AS-i cable (double tap)

Mains connection

Terminals

Terminals

Sensor connection

Terminals

Terminals

Additional
information

page 42

page 42

52001AXX

[1] Mains

AS-i (YE)

AUX-PWR
(BK)

A1

[1]

AS-i (YE)

[1]

A2

The designs listed above are also valid for mounting the MOVIMOT

®

inverter with

option P2.A close to the motor.