3 movimot® inverter (with integrated as-interface), Movimot, Inverter (with integrated as-interface) – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 12

Advertising
background image

12

Operating Instructions – MOVIMOT® MM03C - MM3XC

3

MOVIMOT® inverter (with integrated AS-Interface)

Unit Design

3.3

MOVIMOT

®

inverter (with integrated AS-Interface)

06413AXX

1. Screw for PE connection

2. Terminal box (size 1 used as example)
3. Identification of the circuit type
4. Connection plug between connection unit and inverter
5. MOVIMOT

®

inverter with heat sink (size 1 used as example)

6. Switch S5 (AUX/24 V supply, for settings see the section "Startup")
7. Electronics terminal strip X2
8. Connection of brake coil (X3). For motors without brake: Connection of internal

braking resistor BW. (standard)

9. Mains connection L1, L2, L3 (X3) (suitable for 2 x 4 mm

2

)

10. Screw for PE connection

11. Connection unit with terminals
12. Cable glands
13. Diagnostic interface (see the section "Diagnostics")
14. AS-i connection
15. Electronics nameplate
16. Safety hood for inverter electronics
17. Setpoint potentiometer f1 (not visible), accessible from top of MOVIMOT

®

inverter

via screw fitting

18. Setpoint switch f2 (green)
19. Switch t1 for generator ramp (white)
20. DIP switches S3 and S4 (for settings see the section "Startup")
21. Status LEDs (visible from top of MOVIMOT

®

inverter, see the section "Diagnostics")

3

2

4

11

7

8

9

13

1

10

5

15

16

17

18

19

20 21

6

14

12