16

Operating Instructions – MOVIMOT® MM03C - MM3XC

4

MOVIMOT® gearmotor

Mechanical Installation

4

Mechanical Installation

4.1

MOVIMOT

®

gearmotor

Before you begin

Install MOVIMOT

®

only if

the entries on the nameplate of the drive match the voltage supply system,

the drive is undamaged (no damage caused by transport or storage).

it is certain that the following requirements have been fulfilled:

– Ambient temperature between –25 °C and +40 °C (remember that the tempera-

ture range of the gear unit may be restricted

operating instructions for the gear

unit)

– No oil, acid, gas, vapors, radiation, etc.


Installation toler-
ances

Mounting
MOVIMOT

®

The MOVIMOT

®

may only be mounted or installed in the specified mounting position

on a level, vibration-proof and torsionally rigid support structure.

Thoroughly remove anti-corrosion agents from the shaft extensions (use a commer-
cially available solvent). Do not allow the solvent to penetrate the bearings and shaft
seals – this could cause material damage!

Carefully align MOVIMOT

®

and the driven machine, to avoid placing any unaccept-

able strain on the motor shafts (observe permissible overhung load and axial thrust
data!).

Do not butt or hammer the shaft end.

Use an appropriate cover to protect motors in vertical mounting positions from ob-
jects or fluids entering!

Ensure an unobstructed cooling air supply and that air heated by other apparatus
cannot be drawn in or reused.

Balance components for subsequent mounting on the shaft with a half key (output
shafts are balanced with a half key).

Any condensation drain holes are closed with plastic plugs and must not be opened
unless needed.

Do not leave any condensation drain holes open, since this defeats higher enclosure
ratings.

Installation in
damp areas or in
the open

Use suitable screwed cable glands for the supply leads (use reducing adapters if
necessary).

Coat the threads of cable glands and pocket caps with sealant and tighten them well
– then coat them again.

Seal the cable entry well.

Clean the sealing faces of the MOVIMOT

®

inverter well before re-assembly.

Restore the anticorrosive coating if necessary.

Check the type of enclosure is authorized (refer to the nameplate).

Shaft end

Flanges

Diametric tolerance in accordance with DIN 748

ISO k6 at

50 mm

ISO m6 at

> 50 mm

(Center bore in accordance with DIN 332, shape
DR)

Centering shoulder tolerance in accordance with
DIN 42948

ISO j6 at

230 mm

ISO h6 at

> 230 mm

Advertising