C1 c2 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 41

Advertising
background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

41

6

Connection options with integrated AS-Interface

Electrical Installation with Integrated AS-Interface

C

Design with AND3/AZSK plug connector

(3 x M12 plug, 1 x Han Q8/0):

Design

C1

C2

C3

Type designation

MM../RJ.A/AND3/AZSK

MM../RJ.A/AND3/AZSK

MM../RJ.A/AND3/AZSK

Switch S5

1

1

0

24 V supply

AUX-PWR cable

AUX-PWR cable (double
tap)

Yellow AS-i cable

AS-i connection

Yellow AS-i cable

Yellow AS-i cable (double
tap)

Yellow AS-i cable

Mains connection

AND3 plug connector

AND3 plug connector

AND3 plug connector

Sensor connection

M12 plug connector

M12 plug connector

M12 plug connector

Additional
Information

page 44

page 44

page 44

51761AXX

[1] Mains

2 x DI

2 x DI

AS-i (YE)

AUX-PW
(BK)

2 x DI

[1]

C1

C2

AS-i (YE)

AUX-PWR (BK)

C3

AS-i (YE)

[1]

[1]

The designs listed above are also valid for mounting the MOVIMOT

®

inverter with

option P2.A close to the motor.